http://SOLUTIONSCOMMUNICATIONS.IN
SOLUTIONSCOMMUNICATIONS 5ac74fba6a63e101bcbb61cb False 1359 80
OK
background image not found
Found results for
'aspirating smoke detector'
Xtralis VESDA VLF (LaserFOCUS) Aspirating Smoke Detector INR   0 INR  0
-NaN%

Xtralis VESDA VLF (LaserFOCUS) Aspirating Smoke Detector

VESDA VLF (LaserFOCUS) Aspirating Smoke Detector: Out-of-the-box installation and commissioning Ultrasonic airflow sensing Laser-based absolute smoke detection Pre-engineered pipe network designs Programmable alarm thresholds Clean air barrier optics protections Instant recognition display Instant Fault Finder™ AutoLearn™ Smoke AutoLearn™ Flow Field service access door Multiple event logging (in separate logs), up to 18,000 events Offline/online configuration capability

INR 0 INR 0

Availability:True

Pay mode:COD only

view details
Bosch Fire Panel 2LOOP INR   0 INR  0
-NaN%

Bosch Fire Panel 2LOOP

The FPA‐1000‐UL Analog Addressable Fire Panel is an advanced analog control panel for small to medium facilities in commercial or public building applications. The FPA‐1000‐UL combines complete built-in Fire Alarm Control Panel (FACP) equipment such as Notification Appliance Circuits (NACs), Signaling Line Circuits (SLCs), relays, power supply, Digital Alarm Communicator Transmitter (DACT), and Ethernet connection with expandability using the option bus or plug‐in boards. The two integrated NACs can be expanded with remote addressable NAC power boosters and programmed with specific activation patterns. Features: Support for up to 508 points on two analog addressable loops Built‐in Ethernet connector for web‐browser based programming and ConettixIP Alarm-over-IP communication Carbon Monoxide Detector (gas) support meets NFPA 720 (2009) requirements for visual and audible annunciation Auto‐Learn mode for easy provisioning On‐line help and off‐line programming capability provide simple configuration and service. Trouble conditions. The built‐in keypad can be used for total system control and programming even when wearing fireman gloves. In addition, a large 4‐line by 20‐character alphanumeric LCD display shows programmed device point information. Four keys enable Drill, Reset, Silence, and Acknowledge functions. The FPA‐1000‐UL enables various programming approaches: Two different phone or IP numbers Different dialing types for PSTN (pulse only, tone and pulse, or tone only) Individual PSTN line supervision (audible and visual trouble signal in the case of a transmission path failure) Selectable options for Report Steering Groups Programmable acknowledge wait time for each IP reporting Conettix account (15 sec up to 255 sec) Test call frequency individually programmable for each account (4, 12, 24 hour, 7 and 28 day intervals, standard frequency 24 hour) Notification Appliance Circuits (NACs): Two Class A Style Z or Class B Style Y NACs provide up to 4 A of 24 V power (non-synchronized: 2.5 A per NAC; synchronized: 2.75 A NAC 1 + NAC 2 in total) to operate horns, strobes, bells, and other notification appliances. Each NAC can be programmed to provide Temporal Code 4, Temporal Code 3, and steady, puls- ing, and synchronized protocol output for Wheelock, Gentex, and System Sensor notification appliances. Signaling Line Circuits (SLCs): The Bosch FPA‐1000‐UL Fire Panel uses the patented DCP Digital Communication Protocol to communicate with each of the analog addressable devices located on the SLCs. This fast and reliable protocol allows the use of standard non‐twisted, non‐shielded wiring for the SLCs. The FPA‐1000‐UL supports two Class B, Style 4 or one Class A, Style 6 or 7 per SLC. Mounting Considerations: The cabinet can be either semi-flush (requires optional FPM‐1000‐SFMK Semi-flush Mounting Kit) or surface mounted. Depending on the configuration and the battery selection, the FPA‐1000‐UL can be quite heavy. When attaching the enclosure to a surface, use mounting hardware (not supplied) capable of supporting this weight, and reinforce the wall as necessary. Wiring Considerations: The length of wire allowed between the control panel and the last device on a wiring run depends on the current drawn on that wiring run. Reducing the number of devices on a wiring run allows the individual runs to be longer.

INR 0 INR 0

Availability:False

Pay mode:COD only

view details
COOPER Addressable Sensors INR   0 INR  0
-NaN%

COOPER Addressable Sensors

Photoelectric smoke sensor (opto) is suitable for most applications giving the fastest response to slow burning or smouldering fires which give rise to large visible smoke particles. Opto-heat sensor will respond better to fast clean burning fires yet maintain the advantage of optical sensors when detecting smouldering fires. The thermal enhancement of this sensor allows a higher alarm threshold which provides a greater rejection of false alarms. The sensor will also give an alarm at temperatures above 135°F. Rate of rise with fixed heat sensor settings will detect a rapid increase in temperature or temperatures above 135°F and should be used in environments where the ambient conditions might cause false alarms if smoke detection were to be used, for example where there is a high level of dust, fumes, steam or smoke under normal conditions. Fixed heat sensors settings will detect temperatures above 135°F or 194°F and should be used in environments where the ambient conditions might cause false alarms if smoke detection were to be used, for example where there is a high level of dust, fumes, steam or smoke under normal conditions. For photoelectric and opto-heat operation the sensor automatically compensates for gradual increase in the scatter signal due to contamination e.g. dust build up. Features Built-in short circuit isolators Stylish low profile design 360º viewable LED design Removable detector chamber Drift compensation Benefits Plug and play - no hard addressing required ‘Clean me’ feature means sensor can be cleaned on site using the Menvier manual cleaning procedure The programmable heat sensor reduces the number of parts required in the system

INR 0 INR 0

Availability:True

Pay mode:COD only

view details
TEXECOM INTRUSION INR   0 INR  0
-NaN%

TEXECOM INTRUSION

Texecom Intruder Products :Wireless PIR Motion, Wireless Smoke or Heat detector, Wireless Keyped, Intrusion Panel, Wireless Glass Break or Vibration Detectors, CMS Software etc.

INR 0 INR 0

Availability:True

Pay mode:COD only

view details
TEXECOM : TXIAEC0018 ( Wired Glass Break Detector - Acoustic) INR   0 INR  0
-NaN%

TEXECOM : TXIAEC0018 ( Wired Glass Break Detector - Acoustic)

TEXECOM : TXIAEC0018 ( Wired Glass Break Detector - Acoustic) Texecom Impaq Glassbreak. Audio Based •Microprocessor Design •Quad Frequency Analysis •9m Maximum Range •Ultra Wide 170˚ Detection Angle •Digital Flex Detection For Improved False Alarm Immunity •Glass Type Selection: Plate/Tempered/Laminated/Wired •Adjustable Sensitivity •Test Mode

INR 0 INR 0

Availability:True

Pay mode:COD only

view details
TEXECOM Model : TXIAEA0012 (Wired Vibration Detector) INR   0 INR  0
-NaN%

TEXECOM Model : TXIAEA0012 (Wired Vibration Detector)

TEXECOM Model : TXIAEA0012 (Wired Vibration Detector-White) TEXECOM Model : TXIAEA0014 (Wired Vibration Detector-Brown) Texecom Impaq E – Brown/White, Shock Sensor . Vibration Based •Dual Sensitivity Range •Normally closed (fail-safe) voltage free contacts •Fully Adjustable Detection •Ultra High False Alarm Immunity •Selactable LED Indication

INR 0 INR 0

Availability:True

Pay mode:COD only

view details
TEXECOM Model : TXIAED0009 ( Wired VIBRATION Detector + MC) INR   0 INR  0
-NaN%

TEXECOM Model : TXIAED0009 ( Wired VIBRATION Detector + MC)

Digital shock sensor (White) with magnetic contact and Double reed switches - One device for Double Protection on opening doors and windows. - Digital Microprocessor Technology - Tri-Colour LED Indication - Separate Reed Switch & Shock Sensor Alarm Outputs - Includes All Impaq E Features

INR 0 INR 0

Availability:True

Pay mode:COD only

view details
TEXECOM Wireless Smoke & Heat INR   0 INR  0
-NaN%

TEXECOM Wireless Smoke & Heat

Texecom Model : TXIGBN0003 ( Wireless Smoke & Heat) Texecom Premier Elite OH-W Optical and Heat Fire Sensing multi function Detector Texecom Ricochet mesh technology for unmatched wireless range 85dB(A) built-in sounder Powered by 3 x AAA batteries (included) Remotely check – Battery, Health, Signal and Device Status on Ricochet Software Manufactured in partnership with Apollo • Average battery life between 9-12 months

INR 0 INR 0

Availability:True

Pay mode:COD only

view details
1